Compact ATSE for straightforward integration in modular DIN enclosure, tailor made transfer set up and preventive maintenance perform

Guarantee an supreme redundancy for crisis gensets Back up your entire distribution right up for the significant loads Market Shut

ATyS C25 can be an entry amount ATSE controller with communications. It can be used to pilot a remotely operated transfer switch, like ATyS r, ATyS S and ATyS d M, and also contactors.

In addition to their built-in energy and Electricity measurement capabilities (having a 2% precision stage), programmable inputs/outputs can be utilised to control load shedding determined by a load amount or tariff.

They are really intended to be used in low voltage electricity source techniques where by a brief interruption on the load source is acceptable through transfer.

Protected ATyS p M have the two electrical and mechanical interlocks for optimum stability. Additionally they feature a favourable split indicator, confirming switch situation with dual mechanical indicators for increased basic safety.

Effortless integration ATyS d S merchandise might be very easily set up inside enclosures. Their design, and especially their compact dimensions, allows integration inside most two hundred mm deep enclosures.

Immediate commissioning Voltage tapping and cable harness are supplied in one package with motorised transfer change

On top of that, they do not require a electrical power offer to take care of posture, thus defending their masses from voltage fluctuations.

Recording of events ATyS p switches empower efficient checking within your installation as a result of timestamped event recording.

Together with enhanced electrical performances, ATyS p give a higher amount of basic safety in the whole installation lifecycle.

Probability to set periodic genset startup Chance to set periodic genset startup ATyS p switches give more info supplemental features for upkeep. They consist of a programmable genset beginning function which will allow the starting off dates and working occasions to generally be configured.

Vitality backup The integrated Strength backup delivers transitional power towards the solution enabling standing sign (change placement, timer standing, fault notifications) and conversation to remain Energetic without any provide current for approximately 30 seconds.

Easy Config Procedure program Configure your Socomec measuring and cargo breaking tools Program method for a more rapidly, additional reputable and even more flexible configuration within your electricity monitoring procedure